Danfoss helps you optimize the design of the refrigerant circuit
Commercial glass door merchandisers keep foods, cans and bottles cool in shops, supermarkets, convenience stores and gas stations.
The most important requirements for glass door refrigerators, commercial glass door fridges and coolers are low noise level, compactness, and high energy efficiency.
The trend of climate-friendly solutions is growing, and consequently many drink manufacturers have made it their hallmark to reduce their carbon footprint, among others by using low GWP refrigerants in their glass door merchandisers.
Danfoss can offer you a full range of components certified for the majority of refrigerants and full, technical support to help you optimize the design of the refrigerant circuit.
准备使用天然制冷剂扩展投资组合
Danfoss encourages the industry to continue to speed up its contribution to a cleaner environment and a cleaner image.
Features and benefits
Expansion valves for high energy efficiency
Mechanical and electronic thermostats for precise temperature control
Electric controllers for energy management and equipment control
Micro channel heat exchangers for reducing refrigerant charge, improved efficiency and compactness
Compressors: SC, NL, NLE, DLE, BD (Solar) for self-contained units
从玻璃门商品中获得最好的东西
Documents
Type | Name | 语言 | Valid for | Updated | Download | 文件类型 |
---|---|---|---|---|---|---|
小册子 | ERC-ETC | 英语 | 多种的 | 2014年10月20日 | 277.0 kb | |
Article | Food safety Focus on system performance, reliability and connectivity | 英语 | 多种的 | 2018年12月20日 | 483.0 KB | |
小册子 | MCHE -time and cost saving | Korean | 多种的 | 2015年4月7日 | 6.8 MB | |
Data sheet | Thermostatic expansion valve Type TD 1 / TDE 1 | 英语 | 多种的 | 25 Oct, 2021 | 2.2 MB |
Related products
Solenoid Valves for refrigeration applications, standard types for fluorinated refrigerants and ammonia (R717) as well as solenoid valves for water and brine. The category also contains solenoid valves in stainless steel, gas powered valves and pulse solenoid valves.
","StartDate":null,"EndDate":null,"Location":null,"EventTypes":null,"HasErrors":false,"HasWarnings":false,"Errors":[],"Warnings":[]},{"Id":"https://danfoss-webex-umbraco-prodgreen.azurewebsites.net/en/products/dcs/valves/thermostatic-expansion-valves/thermostatic-expansion-valves/t2-te2/","FormattedStartDate":null,"FormattedEndDate":null,"Link":{"NewWindow":false,"Url":"/en/products/dcs/valves/thermostatic-expansion-valves/thermostatic-expansion-valves/t2-te2/"},"IsExternalLink":false,"Title":"T2 / TE2 thermostatic expansion valves, exchangeable orifice","Image":"/media/2260/te-2-danfoss.jpg","ImageAltText":"T2/TE2 thermostatic expansion valves - Danfoss","Description":"T2 / TE2 thermostatic expansion valves are used for liquid injection into evaporators on both refrigeration and air conditioning systems using fluorinated refrigerants. T2 / TE2 is supplied with an interchangeable orifice assembly for easy stocking and service.
","StartDate":null,"EndDate":null,"Location":null,"EventTypes":null,"HasErrors":false,"HasWarnings":false,"Errors":[],"Warnings":[]},{"Id":"https://danfoss-webex-umbraco-prodgreen.azurewebsites.net/en/products/dcs/valves/thermostatic-expansion-valves/thermostatic-expansion-valves/td-1/","FormattedStartDate":null,"FormattedEndDate":null,"Link":{"NewWindow":false,"Url":"/en/products/dcs/valves/thermostatic-expansion-valves/thermostatic-expansion-valves/td-1/"},"IsExternalLink":false,"Title":"TD 1 thermostatic expansion valves, fixed orifice","Image":"/media/2247/td-1-danfoss.jpg","ImageAltText":"TD 1 thermostatic expansion valves - Danfoss","Description":"TD1 / TDE 1 is a thermostatic expansion valve designed to regulate liquid injection into evaporators with smaller capacities in refrigeration, heat pump and air conditioning systems. The liquid injection depends on the refrigerant superheat at the evaporator outlet, where the bulb must be placed.
","StartDate":null,"EndDate":null,"Location":null,"EventTypes":null,"HasErrors":false,"HasWarnings":false,"Errors":[],"Warnings":[]},{"Id":"https://danfoss-webex-umbraco-prodgreen.azurewebsites.net/en/products/dcs/electronic-controls/electronic-temperature-control/eet-electronic-temperature-controls/","FormattedStartDate":null,"FormattedEndDate":null,"Link":{"NewWindow":false,"Url":"/en/products/dcs/electronic-controls/electronic-temperature-control/eet-electronic-temperature-controls/"},"IsExternalLink":false,"Title":"EET – Electronic thermostats","Image":"/media/d1tplcix/eet-electronic-thermostats.jpg","ImageAltText":"EET – Electronic thermostats - Danfoss","Description":"The EET electronic thermostats are designed to enhance efficiency and improve reliability of food service equipment.
","StartDate":null,"EndDate":null,"Location":null,"EventTypes":null,"HasErrors":false,"HasWarnings":false,"Errors":[],"Warnings":[]}]" data-group-type="product">-
if (isSmallPicture) {} else if(isbigcolumns){} else {}Hydrocarbon compressors
R290 & R600a: Danfoss propane and isobutane compressors – tailored for light commercial refrigeration applications.
-
if (isSmallPicture) {} else if(isbigcolumns){} else {}Solenoid valves for HVAC-R
用于制冷应用的螺线管阀,荧光制冷剂和氨的标准类型(R717)以及水和盐水的电磁阀。该类别还包含不锈钢,气体动力和脉冲电磁阀中的电磁阀。
-
if (isSmallPicture) {} else if(isbigcolumns){} else {}T2 / TE2 thermostatic expansion valves, exchangeable orifice
T2 / TE2恒温膨胀阀用于使用氟化制冷剂的冷藏和空调系统的蒸发器注射液体。T2 / TE2提供可互换的孔口组件,可轻松放养和服务。
-
if (isSmallPicture) {} else if(isbigcolumns){} else {}TD 1恒温膨胀阀,固定孔口
TD1 / TDE 1 is a thermostatic expansion valve designed to regulate liquid injection into evaporators with smaller capacities in refrigeration, heat pump and air conditioning systems. The liquid injection depends on the refrigerant superheat at the evaporator outlet, where the bulb must be placed.
-
if (isSmallPicture) {} else if(isbigcolumns){} else {}EET - 电子恒温器
The EET electronic thermostats are designed to enhance efficiency and improve reliability of food service equipment.
Related solutions
即将推出...
即将推出...
Case stories
So how do you achieve the desired energy efficiency, operational accuracy and safety of Glass Door Merchandisers? In this article we will explore some of the advantages provided by electronic thermostats & controllers, when compared to traditional electromechanical thermostats in order to support you in your choice of temperature control device
","StartDate":null,"EndDate":null,"Location":null,"EventTypes":null,"HasErrors":false,"HasWarnings":false,"Errors":[],"Warnings":[]},{"Id":"https://danfoss-webex-umbraco-prodgreen.azurewebsites.net/en/service-and-support/case-stories/dcs/solid-core-with-steel-housing-vs-loose-desiccant-with-spun-copper-tube/","FormattedStartDate":null,"FormattedEndDate":null,"Link":{"NewWindow":false,"Url":"/en/service-and-support/case-stories/dcs/solid-core-with-steel-housing-vs-loose-desiccant-with-spun-copper-tube/"},"IsExternalLink":false,"Title":"Solid core with steel housing vs loose desiccant with spun copper tube: Choose the right filter drier technology","Image":"/media/3763/solid-core-with-steel-housing-vs-loose-desiccant-with-spun-copper-tube.jpg","ImageAltText":"Solid Core with Steel Housing vs Loose Desiccant with Spun Copper Tube","Description":"Filter driers are key components in any commercial or residential refrigeration application. The market for filter drier technology, however, is complex with a lot of different solutions available and great variation when it comes to quality and pricing.
\nChoosing the right filter drier is essential to providing reliable, long lasting protection of any refrigeration system.
","StartDate":null,"EndDate":null,"Location":null,"EventTypes":null,"HasErrors":false,"HasWarnings":false,"Errors":[],"Warnings":[]},{"Id":"https://danfoss-webex-umbraco-prodgreen.azurewebsites.net/en/service-and-support/case-stories/dcs/choosing-the-right-component-thermostatic-expansion-valve-vs-capillary-tube-in-glass-door-merchandisers/","FormattedStartDate":null,"FormattedEndDate":null,"Link":{"NewWindow":false,"Url":"/en/service-and-support/case-stories/dcs/choosing-the-right-component-thermostatic-expansion-valve-vs-capillary-tube-in-glass-door-merchandisers/"},"IsExternalLink":false,"Title":"Choosing the right component: thermostatic expansion valve vs capillary tube in glass door merchandisers","Image":"/media/7495/cr-tombstone-danfoss.jpg","ImageAltText":"CR Tombstone Danfoss","Description":"With a growing focus on reducing their environmental footprint and reducing costs, manufacturers of Glass Door Merchandisers (GDMs) are looking for alternatives to optimize their equipment in order to save energy and improve the efficiency of the system Depending on the condition of the equipment and the environment, choosing the right component can bring significant advantages
","StartDate":null,"EndDate":null,"Location":null,"EventTypes":null,"HasErrors":false,"HasWarnings":false,"Errors":[],"Warnings":[]},{"Id":"https://danfoss-webex-umbraco-prodgreen.azurewebsites.net/en/service-and-support/case-stories/dcs/low-gwp-refrigerants-an-attractive-choice-for-glass-door-merchandisers/","FormattedStartDate":null,"FormattedEndDate":null,"Link":{"NewWindow":false,"Url":"/en/service-and-support/case-stories/dcs/low-gwp-refrigerants-an-attractive-choice-for-glass-door-merchandisers/"},"IsExternalLink":false,"Title":"Low GWP refrigerants, an attractive choice for glass door merchandisers","Image":"/media/5817/danfoss-logo_1120x747.png","ImageAltText":"Low GWP refrigerants, an attractive choice for glass door merchandisers","Description":"This article explores the opportunities for the low GWP refrigerants and seeks to answer some of the questions to help you find the right solution
","StartDate":null,"EndDate":null,"Location":null,"EventTypes":null,"HasErrors":false,"HasWarnings":false,"Errors":[],"Warnings":[]}]" data-group-type="case-study" data-check-all-label="Explore more" data-redirect-url="">-
if (isSmallPicture) {} else if(isbigcolumns){} else {}Danfoss ADC lab testing helps Haglund improve energy efficiency by 34%
Refrigeration manufacturer Haglund Industri AB wanted to achieve energy efficiency class A. Experts at the Danfoss Application Development Center (ADC) rigorously tested new component packages and reported energy savings up to 34%.
-
if (isSmallPicture) {} else if(isbigcolumns){} else {}Electromechanical thermostat or electronic controller – what is the right solution for GDMs?
So how do you achieve the desired energy efficiency, operational accuracy and safety of Glass Door Merchandisers? In this article we will explore some of the advantages provided by electronic thermostats & controllers, when compared to traditional electromechanical thermostats in order to support you in your choice of temperature control device
-
if (isSmallPicture) {} else if(isbigcolumns){} else {}Solid core with steel housing vs loose desiccant with spun copper tube: Choose the right filter drier technology
滤清器是任何商业或住宅制冷应用中的关键组件。但是,过滤器干燥技术的市场很复杂,在质量和价格方面,有许多不同的解决方案以及许多不同的解决方案。
Choosing the right filter drier is essential to providing reliable, long lasting protection of any refrigeration system.
-
if (isSmallPicture) {} else if(isbigcolumns){} else {}Choosing the right component: thermostatic expansion valve vs capillary tube in glass door merchandisers
With a growing focus on reducing their environmental footprint and reducing costs, manufacturers of Glass Door Merchandisers (GDMs) are looking for alternatives to optimize their equipment in order to save energy and improve the efficiency of the system Depending on the condition of the equipment and the environment, choosing the right component can bring significant advantages
-
if (isSmallPicture) {} else if(isbigcolumns){} else {}低GWP制冷剂,玻璃门商品的吸引人选择
This article explores the opportunities for the low GWP refrigerants and seeks to answer some of the questions to help you find the right solution
Contact us
For further information, please联系我们.